The Law Explained

Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020: A Landlord's Guide

The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 require landlords of most private tenancies in England to have the fixed electrical installation inspected and tested at least every five years by a qualified and competent person, and to give copies of the report to tenants and, on request, the council. The report is an Electrical Installation Condition Report, or EICR. This guide explains who the regulations cover, the inspection duty, the copy deadlines, what happens when a report is unsatisfactory and how councils enforce the rules. It applies to England only. All Service 4 U carries out these inspections across Greater London: you can book a landlord electrical safety certificate by phone.

Have your postcode, the number of bedrooms and consumer units, and your current report's next-inspection date ready.

  • NICEIC Approved Contractor since 2021
  • Price confirmed before we attend
  • Phone line open 24/7

Who the Regulations Apply To

The regulations apply to private landlords whose property is let under a tenancy that gives the tenant the right to occupy it as their only or main residence, where rent is paid. That takes in assured shorthold tenancies, assured tenancies, regulated tenancies and licences to occupy of the same kind. They applied to every new tenancy granted from 1 July 2020 and to all existing tenancies from 1 April 2021, so there is no private tenancy of this type that is still outside them.

Schedule 1 lists the tenancies that are exempt: social landlords, lodgers who share accommodation with the landlord or their family, long leases of seven years or more, student halls of residence, hostels and refuges, care homes, hospitals and hospices, and accommodation covered by the Mobile Homes Act. Our guide to which tenancies are exempt goes through each one. The exemption for social landlords is being removed so that the regulations extend to social housing from a commencement date set by the government; until that date is confirmed, treat the extension as pending.

The Five-Year Inspection Duty

The duty is to have the installation inspected and tested at intervals of no more than five years, or sooner where the previous report states a shorter period. The inspection is carried out against the 18th edition of the Wiring Regulations, BS 7671, which sets the electrical safety standards the regulations refer to. It must be done by a qualified and competent person: in practice an electrician whose qualifications, experience and insurance cover the inspection and testing of domestic installations, and who can show them on request.

The report has to record the results, give the date by which the next inspection is due, and list any observations with their classification codes. A brand-new installation does not need an EICR straight away: an Electrical Installation Certificate (EIC) that is less than five years old stands in place of the first report, and the five years run from its date. The timing rules, including what happens when tenants change, are set out in how often a landlord needs an EICR.

Copies, Deadlines and Who Gets the Report

Keep a copy of the current report and hand it to the electrician at the next inspection, so that the next report can refer to it. All of this is part of our landlord electrical safety certificates service.

1

Existing tenants

within 28 days of the inspection, give every current tenant a copy. Email or a paper copy at the property both count; keep proof that it was sent.

2

New tenants

before a new tenant occupies the property, give them a copy of the current report. Many landlords include it in the welcome pack alongside the other pre-tenancy documents.

3

Prospective tenants

anyone who asks for it before deciding whether to rent must receive a copy within 28 days of the request.

4

The local authority

when the council asks in writing, send the copy within 7 days of the request. Councils use this power when they investigate complaints and when they consider licence applications.

When the Report Is Unsatisfactory

A report is unsatisfactory when it contains a C1 (danger present), a C2 (potentially dangerous) or an FI (further investigation required) observation. A C3, which recommends an improvement, does not on its own make the report unsatisfactory. Where the report is unsatisfactory, the landlord must have the remedial work or the further investigation completed within 28 days, or within any shorter period the report states, using a qualified and competent person.

Once that work is done, the landlord needs written confirmation from the person who did it that the work has been carried out and the installation now meets the standards, or that further work is needed. Within 28 days of completion, that written confirmation goes to every tenant and, where it asked for the report, to the council. If a C1 is found, the inspector will tell you on the day: switch off the affected circuit at the consumer unit if it is safe to do so and call a qualified electrician; in an emergency call 999. The full route is in unsatisfactory EICR: the landlord's 28-day duty.

Enforcement: Remedial Notices and Civil Penalties

Enforcement sits with the local housing authority for the borough where the property is. Where the council has reasonable grounds to believe a landlord is in breach, it serves a remedial notice setting out what must be done and giving the landlord 28 days to comply. Where the landlord does not comply, the council can arrange for the remedial action to be carried out itself, with the tenant's consent, and recover its costs from the landlord. Where a report identifies a C1, the council can take urgent remedial action.

The council can also impose a civil penalty of up to thirty thousand pounds per breach. A landlord who receives a notice has the right to make written representations, and a penalty can be appealed to the First-tier Tribunal. Licensing teams apply the same rules alongside licence conditions, which is why our guide to property licensing and EICRs borough by borough sits next to this one.

Tenant Access and Reasonable Steps

A landlord is not in breach of the inspection duty, or of the remedial duty, if they can show that they took all reasonable steps to comply. The most common situation is a tenant who will not allow the electrician in. Write to the tenant with proposed dates, offer alternatives, explain that the inspection is a legal requirement, and keep every message, reply and refusal on file: that written trail is your evidence. The duty continues, and it resumes as soon as access is possible. What to do and record is set out in tenant will not allow access for an EICR.

Related Guides

01

How Often an EICR

How often a landlord needs an EICR: the five-year maximum, the inspector's next-inspection date, what a new tenancy changes, and how an EIC counts.

Read the guide
02

Unsatisfactory EICR

Your EICR is unsatisfactory: what C1, C2 and FI mean, the 28-day remedial deadline, the written confirmation tenants and the council must receive.

Read the guide
03

Licensing by Borough

Which London boroughs run additional and selective licensing, with scheme dates, and what every licence adds to the landlord's national five-year EICR duty.

Read the guide

Landlord electrical safety certificates

Arrange Your Inspection

NICEIC registered electricians carry out every inspection, and your fixed price is confirmed before we attend. Call 020 3740 6785 at any time, day or night, with the property address and the number of bedrooms; evening and weekend appointments are available. The report arrives as a PDF by email, ready to send to your tenants and the council. You can book a landlord electrical safety certificate today.

020 3740 6785

Frequently Asked Questions

Do the regulations apply to my existing tenancy?

Yes. The regulations applied to new tenancies from 1 July 2020 and to all existing tenancies from 1 April 2021, so a tenancy that began before either date is covered unless it falls within one of the Schedule 1 exemptions. If your tenancy has been running for years without a report, the duty still applies now and the five-year interval is counted from the date of the first inspection you have.

When did the regulations come into force?

The regulations came into force on 1 June 2020. They applied to new specified tenancies granted on or after 1 July 2020 and to all existing specified tenancies from 1 April 2021. Since that second date every private landlord in England with a covered tenancy has needed a current report, and the copy and remedial duties have applied in full.

Do I need a new EICR for each new tenant?

No. The report belongs to the installation, not the tenancy, so a change of tenant does not require a new inspection as long as the existing report is still within its five-year period or the shorter date it sets. What you must do is give the new tenant a copy before they occupy the property, and keep the report valid for the whole of their tenancy.

Does a C3 make the report unsatisfactory?

No. A C3 means an improvement is recommended and does not on its own make the report unsatisfactory, so no remedial deadline is triggered by a C3 alone. Only a C1, a C2 or an FI observation makes the overall assessment unsatisfactory. Many landlords choose to act on C3 recommendations anyway, because they often become C2 observations at a later inspection as the installation ages.

Do the regulations apply to housing association homes?

Not at present. Private registered providers of social housing are exempt under Schedule 1, so housing association and council tenants are not covered by these regulations. The government is extending the regulations to social housing as part of its 2025-26 housing reforms, with a commencement date to be confirmed; check the date before relying on it for a social tenancy.

Still have a question or need urgent assistance? Call 020 3740 6785, tell us what has happened and we will tell you what happens next.

Call 020 3740 6785 · 24/7